MegaPulse 10x700-7PF 39:
Surge Tester 10x700-7PF, 2000-7000V, 10x700-7 Voltage Waveform, 40 ohm 1 chnl

  • $5,800.00

MegaPulse 10x700-7PF, bulk cap voltages of 2000-7000V, 10x700uSec Voltage Waveform, 40 ohm 1 chnl. Designed specifically for testing to IEC 60950 and IEC 62368-1, including the Australian Deviation.  Includes self-regulating high-voltage power supply for more stable voltage control. 

Optional TestMinder PF computer control and 1000:1 Oscilloscope output (reference only).  Option IER equips the tester with a switch compliant with IEC 60065, Fig. 7B.

In accordance with the requirements of IEC 60950, IEC 62368-1 and ITU-T Standards, the meter reads the bulk capacitor voltage.  The output voltage will be less (see Datasheet).  Reference Waveform data in "Manuals" link below.  

Calibrated at bulk cap voltages of 1000-7000V to reflect the test points of IEC 60950, IEC 62368-1 and the Australian Deviation. ISO 17025 calibration available. 

Available Options

Reviews (0)

Write a Review

Note: HTML is not translated!
    Bad           Good

Features

  • Built specifically for the Test described in IEC 60950, Annex N, Table N.1, Line 1 and IEC 62368-1, Annex D, Table D.1, Line 1.
  • Charges the bulk capacitor to the required 2.5kV or 7kV (Australian Deviation), using the front panel knob or optionally via USB, see TMM-PF option.
  • Discharge of the 6838V output pulse is controlled by the front panel TEST button or optionally via USB, see TMM-PF option.
  • Meter reads the bulk capacitor voltage per the requirements of IEC 60950.
  • Polarity can be changed by the front panel POLARITY button or optionally via USB, see TMM-PF option.
  • Cables and NIST Calibration Certificate Included; A2LA Calibration optional.
  • One year warranty and unlimited telephone support.

Specifications

For detailed specifications, see Datasheet above.
For detailed specifications, see Datasheet above.

Manuals

Download Manual
MegaPulse 10x700-7PF rev 0.pdf Download Manual
Waveforms/10x700-7PF_Vdur_2k.pdf Download Manual
Waveforms/10x700-7PF_Vdur_7k.pdf Download Manual
Waveforms/10x700-7PF_Vdur_rev_2k.pdf Download Manual
Waveforms/10x700-7PF_Vdur_rev_7k.pdf Download Manual
Waveforms/10x700-7PF_Vpeak_2k.pdf Download Manual
Waveforms/10x700-7PF_Vpeak_7k.pdf Download Manual
Waveforms/10x700-7PF_Vrise_2k.pdf Download Manual
Waveforms/10x700-7PF_Vrise_7k.pdf Download Manual

Contact Us

Corporate Sales Office (USA)

Compliance West USA
650 Gateway Center Way Suite D
San Diego, CA 92102 USA

US Representatives

Product Update Bulletin

Newest Product: HT-3500S RF, "ruggedized" hipot tester

The HT-3500S RF tester is specifically designed for the challenges common to operating in the field. Along with heavy duty internal brackets and a sturdy, shock-absorbing case, this unit includes adjustable voltage output, voltage ramp, test time, leakage current and ground continuity limit settings - all controlled from an easy-to-access front panel. Call for pricing.

Read More

Available: 16A option for CDT-240

Perform one of the most difficult tests required with both speed and accuracy. The CDT-240 now offers a 16A option along with designed presets to implement the plug discharge test as described in IEC 61010, 60065 and 60335.

Read More

MegaPulse Defib 5P reaches EOL - Replaced by D5-PF

Compliance West USA is announcing the EOL (End-of-LIfe) of our MegaPulse Defib 5P series effective 07/14/2015. This unit has been replaced by our MegaPulse D5-PF advanced tester. Compliance West will continue to support, repair and calibrate the Defib 5P throughout the terms of any existing warranty agreements or up until the product's End-of-Support date. Please contact us with any questions.

Read More