This tester is built to the requirements of IEC 60060-1 with a 500 ohm
impedance. For Standards such as EN 62052-11, Clause 7.3.2 and VDE
PM323E, this tester allows impulse testing to determine spacings in lieu
of other requirements. This tester can perform to test parameters
requiring surge voltages
of up to 12kV. The MegaPulse 1.2x50-12.3 500 ohm is built
specifically to conduct these tests. It uses our proprietary High Voltage relay, built to the requirements of IEC 65 Figure 7 b for robustness and complete compliance with the requirements.
In addition, for automated testing, the MegaPulse 1.2x50-12.3 500 ohm is available with TestMinder P, our computer control and test reporting option.
The MegaPulse is used with a general purpose oscilloscope for waveform
capture and evaluation. Please see waveforms in Manuals section, below.
The standard configuration outputs 12.3kV at 0.5J. Can optionally be configured with three additional 0.5J voltage points at 1500, 6000 and 8000 volts.
Available Options
Reviews (0)
Write a Review
Features
Specifications
Output
1.2 uSec rise time and 50 uSec fall time as specified in IEC 60060-1, clause 19 "Standard Lightning Impulse".
Voltage Rise Time
+/- 30%
Voltage Fall Time
+/- 20%
Source Impedance
500ohm +/- 10%
Source Energy
0.5 J +/- 10% (note
achieved at 1500V)
Mode of Operation
Manual Automatic and pulse train management with TestMinder option
The HT-3500S RF tester is specifically designed for the challenges common to operating in the field. Along with heavy duty internal brackets and a sturdy, shock-absorbing case, this unit includes adjustable voltage output, voltage ramp, test time, leakage current and ground continuity limit settings - all controlled from an easy-to-access front panel. Call for pricing.
Perform one of the most difficult tests required with both speed and accuracy. The CDT-240 now offers a 16A option along with designed presets to implement the plug discharge test as described in IEC 61010, 60065 and 60335.
Compliance West USA is announcing the EOL (End-of-LIfe) of our MegaPulse Defib 5P series effective 07/14/2015. This unit has been replaced by our MegaPulse D5-PF advanced tester. Compliance West will continue to support, repair and calibrate the Defib 5P throughout the terms of any existing warranty agreements or up until the product's End-of-Support date. Please contact us with any questions.