HT-10KVPdc Hipot Tester, 0-14kVdc @ 5mA. Ships complete with cables, manual, and Calibration Certificate. Made in the USA. Calibration and Repair services available. Not sure – contact us!
HT-10KVP DC:
SKU: 00-10KP dcHipot Tester
14KVdc @ 5mA
14KVdc @ 5mA
$4,230.00
Features
- HT10000P AC: AC output to 10000 Volts. Delivers 1 through 8 milliamps. Custom outputs to 25 mA.
- HT10000P DC: DC output to 14000 Volts. Delivers 1 through 5 milliamps.
- Logic Controlled, One-button testing. LED indicators. Buzzer upon failure, test terminates. Test termination defeatable by switch on rear panel. Provided with arc detection circuit to properly detect hipot failures.
- Rear panel adjustments; leakage limit, ramp time, test time and voltage.
- Ergonomic design for safety and ease of use.
- High voltage output jack.
- Automatic voltage ramp-down circuit eliminates residual voltage.
- Designed for product development and laboratory use.
- High efficiency design, low power consumption.
- All test leads included.
- Calibrated to NIST standards.
- 1 year warranty
- HTT-1 and HTT-1RHipot and Ground Continuity Function Checker Compatible
Specifications
| Voltage Range | 0-14000 VDC |
| Current Range | 4 mA |
| Input Voltage Requirements | 108-132 V, 50 /60 Hz, 2A max |
| Fuse Requirements | 120 VAC |
| Arc Detect | Separate high Frequency circuit |
| Leakage Detect | Separate Low frequency circuit |
| Ground Continuity | N/A |
| Ground Continuity Current | N/A |
| Test Time Range | 1 – 60 seconds |
| Ramp time Range | 1 – 5 Seconds |
| Voltage Meter Accuracy | ± 2 % |
| Current Meter Accuracy | ±0.1 mA |
| Resistance measure Range | N/A |
| Resistance auto offset Range | N/A |
| Resistance Measure Accuracy | N/A |
| HV shutdown by Ground Fail | N/A |
| Duty cycle | 100% |
| Discharge Time (Resistive Load) | |
| Transformer Output | < 500 VAC |
| Pass/Fail Repeatability | ± 3 % |
| Output connector | High Voltage Jack |
| Display | 4 digits LED display |
| Test indicator | Led indicators |
| Failure Indicator | Led indicators and buzzer |
| Programable | No |
| PLC Interface | No |
| TestLink | N/A |
| Testminder | No |
| Voltage Hold on failure | Available |
| Top Mounted handle | No |
| Test Defeat | Ramp Time, Test Time and Breakdown Fail |
| Autoreset on Pass | Optional |
| Operation Temperature | 15 – 40 °C |
| Relative Humidity Range | 0 – 90 % Non-condensing |
| Dimensions | 10″ wide x 5″ high x 12″ deep |
| Weight | 17.5 Lb |
| Calibration | One year calibration Certificate |
| Test Cords | Return lead, High Voltage Test Lead, Power cord |
| HTS/Schedule B | 9030.39.0100 |
| ECCN | 3B992 |
| What is in the box | Return lead, High Voltage Test Lead, Power cord |