The MegaPulse 1.2x50/8x20-2PF-HR 2/12 ohm is our 5V-2000V, 2.5A-1000A combination tester. It produces a combination test waveform in compliance with EN 61000-4-5 at extremely low voltage, with high accuracy and repeatability.
The Tester features a High Resolution charge voltage in steps of of 0.1V from 5V-200V and steps of 1V from 200V-2000V; 2 Ω and 12 Ω outputs, Output Polarity Switch, with front panel E-Stop switch and Safety Interlock Discharge; with waveform outputs in accordance with IEC 61000-4-5.
The MegaPulse 1.2x50/8x20-2PF-HR 2/12 ohm charges in less than 5 seconds and can pulse every 20 seconds continuously.
Available MUX and DUT Test enclosure options allow integration into an existing Test Station under PLC, TestMinder or LabView control (see below).
Users may opt for computer control via our option TestMinder MegaPulse PF, PLC guided operation with our Relay Isolated
Control board, or directly via third party software via USB/RS232.
Sold with a one year
warranty and calibrated to NIST Standards. ILAC/17025 Cal available.
Available Options
Reviews (0)
Write a Review
Features
Outputs a combination waveform at 5-2000V, 2 ohms.
High Resolution charge Voltage.
Front panel switch allows waveform reversal.
Can be controlled with TestMinder option.
or via PLC or LabView with Option RI.
Outputs up to 5-2000V peak.
Virtual Impedance of 2 and 12 ohms.
Available TestMinder for computer control of long test sequences.
ANSI Calibration good for one year included, A2LA/17025 Calibration optional.
1 year warranty.
Specifications
See Datasheet Link, above.
See Datasheet Link, above.
Pulse Voltage (open circuit): ±5V to 200V (in 0.1V steps) and 201 to 2000V (in 1V steps).
The HT-3500S RF tester is specifically designed for the challenges common to operating in the field. Along with heavy duty internal brackets and a sturdy, shock-absorbing case, this unit includes adjustable voltage output, voltage ramp, test time, leakage current and ground continuity limit settings - all controlled from an easy-to-access front panel. Call for pricing.
Perform one of the most difficult tests required with both speed and accuracy. The CDT-240 now offers a 16A option along with designed presets to implement the plug discharge test as described in IEC 61010, 60065 and 60335.
Compliance West USA is announcing the EOL (End-of-LIfe) of our MegaPulse Defib 5P series effective 07/14/2015. This unit has been replaced by our MegaPulse D5-PF advanced tester. Compliance West will continue to support, repair and calibrate the Defib 5P throughout the terms of any existing warranty agreements or up until the product's End-of-Support date. Please contact us with any questions.