968-B Power Line

  • 968-B Power Line
  • Product Views
Datasheet

Power Line Tests; 2x10s 2500V 1000A waveform; requires CDN:
968-B Power Line

Call for Price

Designed to generate the surge test described in Clause 68.302(d) Power Line Surge. Output voltage is 2500 volts minimum, peak short circuit current is 1000 amperes minimum. A switch is provided for reversal of output polarity. Optional divider network available for oscilloscope connection. This MegaPulse tester has isolated outputs; that is, no ground reference.

The waveform generated is 2x10/2x10, Vp=2500V. To test, the front panel meter is set to 2500V.

A coupling/decoupling network is required to provide isolation between the DUT, the MegaPulse Power Line and the mains power when the pulse is applied. We can supply our CDN 240/15, built to the requirements of EN61000-4-5 and for use on single phase circuits up to 240Vac and up to 15 amps.

Available Options

Reviews (0)

Write a Review

Note: HTML is not translated!
    Bad           Good

Features

  • Generates the waveforms required by TIA/EIA-IS-968 (formerly known as FCC Part 68), Paragraph 68.302, for testing of Unpackaged Registered Terminal Equipment and Registered Protective Circuitry.
  • Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation.
  • Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse within the 968 Series, allowing checks and proof of test setups.
  • 1000:1 BNC Oscilloscope output option allows quick connections and easy evaluation of output waveforms.
  • Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors.
  • Front panel voltage meter shows residual voltage in charging circuit for safer operation.
  • 1-year calibration cycle.
  • All test leads included.
  • 1 year warranty.

Specifications

See Datasheet above for Specifications.
See Datasheet above for Specifications.

Manuals

Download Manual
Megapulse Telephone type B Rev 1.1.pdf Download Manual
Waveforms/TelephonePowerLine_actual_VriseVdur2900Vin.pdf Download Manual
Waveforms/TelephonePowerLine_ideal_voltage.pdf Download Manual
Waveforms/TelephonePowerLine_ideal_current.pdf Download Manual

Contact Us

Corporate Sales Office (USA)

Compliance West USA
650 Gateway Center Way Suite D
San Diego, CA 92102 USA

US Representatives

Product Update Bulletin

Newest Product: HT-3500S RF, "ruggedized" hipot tester

The HT-3500S RF tester is specifically designed for the challenges common to operating in the field. Along with heavy duty internal brackets and a sturdy, shock-absorbing case, this unit includes adjustable voltage output, voltage ramp, test time, leakage current and ground continuity limit settings - all controlled from an easy-to-access front panel. Call for pricing.

Read More

Available: 16A option for CDT-240

Perform one of the most difficult tests required with both speed and accuracy. The CDT-240 now offers a 16A option along with designed presets to implement the plug discharge test as described in IEC 61010, 60065 and 60335.

Read More

MegaPulse Defib 5P reaches EOL - Replaced by D5-PF

Compliance West USA is announcing the EOL (End-of-LIfe) of our MegaPulse Defib 5P series effective 07/14/2015. This unit has been replaced by our MegaPulse D5-PF advanced tester. Compliance West will continue to support, repair and calibrate the Defib 5P throughout the terms of any existing warranty agreements or up until the product's End-of-Support date. Please contact us with any questions.

Read More