Leakage Current Box Config 2 (Perception or reaction Touch)- Compliance to: IEC 60990:2016 Fig 4, IEC 60950-1:2005 Fig D.1, IEC 61010-1:2010 Fig A.1, IEC 60335-1:2012 Cl 13.2, IEC 60065:2014 (Includes access to U1 & U2), IEC 62368:2014

Product Compare (0)
  • Leakage Current Box Config 2 (Perception or reaction Touch)- Compliance to: IEC 60990:2016 Fig 4, IEC 60950-1:2005 Fig D.1, IEC 61010-1:2010 Fig A.1, IEC 60335-1:2012 Cl 13.2, IEC 60065:2014 (Includes access to U1 & U2), IEC 62368:2014
  • Product Views
  • Leakage Current Box Config 2 (Perception or reaction Touch)- Compliance to: IEC 60990:2016 Fig 4, IEC 60950-1:2005 Fig D.1, IEC 61010-1:2010 Fig A.1, IEC 60335-1:2012 Cl 13.2, IEC 60065:2014 (Includes access to U1 & U2), IEC 62368:2014
  • Leakage Current Box Config 2 (Perception or reaction Touch)- Compliance to: IEC 60990:2016 Fig 4, IEC 60950-1:2005 Fig D.1, IEC 61010-1:2010 Fig A.1, IEC 60335-1:2012 Cl 13.2, IEC 60065:2014 (Includes access to U1 & U2), IEC 62368:2014
Datasheet

LCB-2:
Leakage Current Box Config 2 (Perception or reaction Touch)- Compliance to: IEC 60990:2016 Fig 4, IEC 60950-1:2005 Fig D.1, IEC 61010-1:2010 Fig A.1, IEC 60335-1:2012 Cl 13.2, IEC 60065:2014 (Includes access to U1 & U2), IEC 62368:2014

  • $680.00


Compliance West’s line of Leakage Current Networks are built in accordance with IECEE OD-5013, “Leakage (Touch) Current Measurement Instruments”; and are in compliance with IECEE OD-5014, "Instrument Accuracy Limits, specifically "Leakage (Touch) Current" Section; and IEC 60990.  Our Leakage Current Networks use very accurate components which do not drift due to heat or age, and we specially trim each component in each leakage current box we make to be accurate.  We test the devices to be accurate to 5% from 20Hz to 1MHz, and use metal enclosures to minimize interference.

Read Pete Perkins' First Look Evaluation.

Click here to watch a setup video.

Resistors and capacitors have a tolerance of ±1%, verified during the calibration process.     

All components used are designed for low parasitic inductance and capacitance, and the physical layout of the components is optimized for higher frequencies.

The metal box and ground plane of the circuit board are joined via solid contact to provide shielding of the network, and leads are shielded. 

A calibration report including frequency response is provided with each instrument.

Calibration procedure to allow A2LA calibration from 20Hz to 1MHz is included, enabling any lab with sufficient scope to perform. Click here to show a sample A2LA Calibration document from 20Hz to 1Mhz.

Each box ships with the Leakage Current Network embossed on the front panel.  Leads provided are alligator clips, and they can be changed to any desired configuration by the operator in the field.

We provide Leakage Networks for most Standards.

Reviews (0)

Write a Review

Note: HTML is not translated!
    Bad           Good

Features

  • Provides networks for - IEC 61010-1:2010, IEC 60950-1:2005, IEC 60335-1: 2012 and IEC 60990:2016.
  • Portable, lightweight. Measures 2.40 x 1.15 x 4.45 inches.
  • No batteries or power required.
  • Custom test leads available.
  • Provided with NIST Calibration; A2LA calibration available.
  • One year warranty.

Specifications

For specification information, please see Datasheet Link above.
For specification information, please see Datasheet Link above.

Manuals

Download Manual
LCB/LCB Manual Rev 5.pdf Download Manual

Contact Us

Corporate Sales Office (USA)

Compliance West USA
650 Gateway Center Way Suite D
San Diego, CA 92102 USA

US Representatives

Product Update Bulletin

Newest Product: HT-3500S RF, "ruggedized" hipot tester

The HT-3500S RF tester is specifically designed for the challenges common to operating in the field. Along with heavy duty internal brackets and a sturdy, shock-absorbing case, this unit includes adjustable voltage output, voltage ramp, test time, leakage current and ground continuity limit settings - all controlled from an easy-to-access front panel. Call for pricing.

Read More

Available: 16A option for CDT-240

Perform one of the most difficult tests required with both speed and accuracy. The CDT-240 now offers a 16A option along with designed presets to implement the plug discharge test as described in IEC 61010, 60065 and 60335.

Read More

MegaPulse Defib 5P reaches EOL - Replaced by D5-PF

Compliance West USA is announcing the EOL (End-of-LIfe) of our MegaPulse Defib 5P series effective 07/14/2015. This unit has been replaced by our MegaPulse D5-PF advanced tester. Compliance West will continue to support, repair and calibrate the Defib 5P throughout the terms of any existing warranty agreements or up until the product's End-of-Support date. Please contact us with any questions.

Read More