Datasheet

968-B Power Line:
968-B Power Line 2x10s 2500V 1000A waveform; requires CDN

  • $8,300.00

Designed to generate the surge test described in Clause 68.302(d) Power Line Surge. Output voltage is 2500 volts minimum, peak short circuit current is 1000 amperes minimum. A switch is provided for reversal of output polarity. Optional divider network available for oscilloscope connection. This MegaPulse tester has isolated outputs; that is, no ground reference.

The waveform generated is 2x10/2x10, Vp=2500V. To test, the front panel meter is set to 2500V.

A coupling/decoupling network is required to provide isolation between the DUT, the MegaPulse Power Line and the mains power when the pulse is applied. We can supply our CDN 240/15, built to the requirements of EN61000-4-5 and for use on single phase circuits up to 240Vac and up to 15 amps.

Available Options

Reviews (0)

Write a Review

Note: HTML is not translated!
    Bad           Good

Features

  • Generates the waveforms required by TIA/EIA-IS-968 (formerly known as FCC Part 68), Paragraph 68.302, for testing of Unpackaged Registered Terminal Equipment and Registered Protective Circuitry.
  • Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation.
  • Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse within the 968 Series, allowing checks and proof of test setups.
  • 1000:1 BNC Oscilloscope output option allows quick connections and easy evaluation of output waveforms.
  • Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors.
  • Front panel voltage meter shows residual voltage in charging circuit for safer operation.
  • 1-year calibration cycle.
  • All test leads included.
  • 1 year warranty.

Specifications

See Datasheet above for Specifications.
See Datasheet above for Specifications.

Manuals

Download Manual
MegaPulse 968-B Power Line Rev 0.pdf Download Manual
Waveforms/TelephonePowerLine_actual_VriseVdur2900Vin.pdf Download Manual
Waveforms/TelephonePowerLine_ideal_voltage.pdf Download Manual
Waveforms/TelephonePowerLine_ideal_current.pdf Download Manual

Contact Us

Corporate Sales Office (USA)

Compliance West USA
650 Gateway Center Way Suite D
San Diego, CA 92102 USA

US Representatives

Product Update Bulletin

Newest Product: HT-3500S RF, "ruggedized" hipot tester

The HT-3500S RF tester is specifically designed for the challenges common to operating in the field. Along with heavy duty internal brackets and a sturdy, shock-absorbing case, this unit includes adjustable voltage output, voltage ramp, test time, leakage current and ground continuity limit settings - all controlled from an easy-to-access front panel. Call for pricing.

Read More

Available: 16A option for CDT-240

Perform one of the most difficult tests required with both speed and accuracy. The CDT-240 now offers a 16A option along with designed presets to implement the plug discharge test as described in IEC 61010, 60065 and 60335.

Read More

MegaPulse Defib 5P reaches EOL - Replaced by D5-PF

Compliance West USA is announcing the EOL (End-of-LIfe) of our MegaPulse Defib 5P series effective 07/14/2015. This unit has been replaced by our MegaPulse D5-PF advanced tester. Compliance West will continue to support, repair and calibrate the Defib 5P throughout the terms of any existing warranty agreements or up until the product's End-of-Support date. Please contact us with any questions.

Read More