UL 746E Section 19 covers requirements for conformal coatings used
instead of electrical spacings to increase the dielectric withstand
voltage between traces on a printed-wiring board. Paragraph 19.3
outlines a Voltage transient test to be applied to a specific test
pattern allows testing to determine spacings. The Surge Generator circuit is specified in UL 746E, Figure 19.2
is contained in the MegaPulse 746E. One press of the MegaPulse 746E
TRIGGER button conducts the test suite as described in UL 746E, Para.
19.3. See the schematic in the Datasheet section on this page.
Note: Voltages 400V and over are certified to be in accordance with the tolerances of IEC 1180-1, Para. 6.2.2.
Provided with external interlock control.
In addition, for automated testing, the MegaPulse 746E is available with TestMinder, our computer control and test reporting option. Use with a 32 bit Windows computer.
Provided with NIST Calibration Certificate good for one year. A2LA Calibration available.
The HT-3500S RF tester is specifically designed for the challenges common to operating in the field. Along with heavy duty internal brackets and a sturdy, shock-absorbing case, this unit includes adjustable voltage output, voltage ramp, test time, leakage current and ground continuity limit settings - all controlled from an easy-to-access front panel. Call for pricing.
Perform one of the most difficult tests required with both speed and accuracy. The CDT-240 now offers a 16A option along with designed presets to implement the plug discharge test as described in IEC 61010, 60065 and 60335.
Compliance West USA is announcing the EOL (End-of-LIfe) of our MegaPulse Defib 5P series effective 07/14/2015. This unit has been replaced by our MegaPulse D5-PF advanced tester. Compliance West will continue to support, repair and calibrate the Defib 5P throughout the terms of any existing warranty agreements or up until the product's End-of-Support date. Please contact us with any questions.