In additon to our standard production line testers used to judge acceptability of products to product safety standards, Compliance West USA also offers hipot testers for special uses. This page details our offerings for 5kV-7kV hipot testers.
If you don't see exactly what you need, please contact us with your requirements.
HT5000 •
HT5000-20mA (AC or DC Tester) •
HT5000-20mA-I (AC/DC Tester in 3U case)
HT5000AC-200mA •
HT5000-200mA (AC or DC )Tester)
HT5000
Our HT5000 standard laboratory tester has AC and DC output, for regular insulation work. Leakage current limits can be set with the rear panel knob from 0.5mA to 10mAac or 0.25mA to 5mA dc. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to examine problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.
Packaged in the above enclosure. Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.
Option TM: TestMINDER automation software
Option RI: PLC Interface Board
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output
Option HTT-1: HTT-1 Hipot and Ground Continuity Function Checker
240-220 or 240V operation (requires 3U enclosure)
HT5000-20mA
Our HT5000-20mA has AC or DC output. Leakage current limits can be set with the rear panel knob from 1mA to 20mA. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to burn problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.
Packaged in a normal HT-5000 enclosure. Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.
Option TM: TestMINDER automation software
Option RI: PLC Interface Board
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output
240-220 or 240V operation (requires 3U enclosure)
HT5000-20mA-I
Our HT5000-20mA-I has AC and DC output. Leakage current limits can be set with the front panel knob from 1mA to 20mAac and 0.5mA to 10mAdc. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.
Packaged in a 3U enclosure. Provided with test leads terminated in alligator clips and a calibration certificate traceable to NIST per MIL-STD-45662-A; one year warranty on parts and labor. Photo shows a representative model.
Option TM: TestMINDER automation software
Option RI: PLC Interface Board
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output
Option RF: Continuous operation' switch selects between RF and standard Timer operation.
Option ZOS: Requires the operator to reset the voltage knob to its minimum position before the TEST button can be pressed.
HT5000AC-200mA
Our HT5000AC-200mA has AC output only. Leakage current limits can be set with the rear panel knob from 10mA to 200mA. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to burn problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.
Packaged in a 3U enclosure, with all controls and switches on the front panel for easier access. (Representative model shown).
Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.
Option RI: PLC Interface Board
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output
HT5000-200mA
Our HT5000-200mA has AC and DC output, each capable of 200mA output. Leakage current limits can be set with the front panel knob from 10mA to 200mA. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to burn problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.
In any device, lower ripple voltages require larger filter capacitors, which store more power, and that power is normally used to smooth the rectified waveform. In the case of a hipot tester, this stored power has the side effect of discharging into the EUT in the event of a failure. In order to keep the power that must be absorbed by the EUT within reasonable limits, we have used three phase input power for this model, which improves ripple without the side effect of excessive power sent to the EUT when a dielectric breakdown is detected.
Packaged in a 6U enclosure, with all controls and switches on the front panel for easier access. (Representative model shown).
Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.
Option RI: PLC Interface Board
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output