In additon to our standard production line testers used to judge acceptability of products to
product safety
standards, Compliance West USA also offers hipot testers for special uses.
This page details our
offerings for 3kV hipot testers:
If you don't see exactly what you need, please contact us with your requirements.
HT3000AC-1A
Our HT3000AC-1A is an AC only tester, with the ability to deliver up to 1A to the EUT. Leakage current limits can be set with the front panel knob from 50mA to 1A. The HT3000AC-1A stops testing and sounds a buzzer when a leakage current greater than the set leakage current flows.
Safety options available include external interlock, safe voltage indicator output, and zero voltage output start.
Packaged in a 9U enclosure. Provided with test leads terminated in alligator clips and a calibration certificate to MIL-STD-45662-A; one year warranty on parts and labor.
Option TM: TestMINDER automation software
Option RI: PLC Interface Board
Option VF: Voltage hold on failure
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output
Option ZOS: Requires voltage knob to be set to lowest output before tester will start another test.
Option RF: Continuous operation. Front panel switch selects between normal timer operation and always on operation.
HT3000AC-500mA
Our HT3000AC-500mA is an AC only tester, with the ability to deliver up to 500mA to the EUT. Leakage current limits can be set with the front panel knob from 25mA to 500mA. Normal operation stops testing when a leakage current greater than the set amount is encountered, and a buzzer sounds, alerting the operator
Safety options available include external interlock, safe voltage indicator output, and zero voltage output start.
Packaged in a 6U enclosure. Provided with test leads terminated in alligator clips and a calibration certificate to MIL-STD-45662-A; one year warranty on parts and labor.
Option TM: TestMINDER automation software
Option RI: PLC Interface Board
Option VF: Voltage hold on failure
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output
Option ZOS: Disables TEST Switch until Voltage Knob is reset to the lowest output. Voltage output will always be less than 30 volts at the time the test starts for safety.
Option RF: Continuous operation. Front panel switch selects between normal timer operation and always on operation.
HT3000DC-500mA
Our HT3000DC-500mA is a DC only tester, with the ability to deliver up to 500mA to the EUT. Leakage current limits can be set with the front panel knob from 25mA to 500mA. Normal operation stops testing when a leakage current greater than the set amount is encountered and a buzzer sounds, alerting the operator.
Safety options available include external interlock, safe voltage indicator output, and zero voltage output start.
Packaged in a 6U enclosure. Provided with test leads terminated in alligator clips and a calibration certificate to MIL-STD-45662-A; one year warranty on parts and labor.
Option TM: TestMINDER automation software
Option RI: PLC Interface Board
Option VF: Voltage hold on failure
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output
Option ZOS: Disables TEST Switch until Voltage Knob is reset to the lowest output. Voltage output will always be less than 30 volts at the time the test starts for safety.
Option RF: Continuous operation. Front panel switch selects between normal timer operation and always on operation.