Special-Use Hipot Testers up to 1kV

In additon to our standard production line testers used to judge acceptability of products to product safety standards, Compliance West USA also offers hipot testers for special uses. This page details our offerings for 1kV hipot testers.

If you don't see exactly what you need, please contact us with your requirements.

 

HT1000AC-300mA

HT1000AC-300mA imageOur HT1000AC-300mA is an AC only tester, with the ability to deliver up to 300mA to the EUT. Leakage current limits can be set with the front panel knob from 15mA to 300mA. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to burn problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.
Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.

Output: 0-1000Vac, set by front panel knob
Leakage Current Limit: 15mA-500mA set by front panel knob
Dielectric Breakdown: Defeatable, by high frequency detection circuit
Test Time: Defeatable, 0-60 sec. by front panel knob
Ramp Time: Manual only
Duty Cycle: 100%
Input Power: 120V 3A

Option RI: PLC Interface Board
Option VF: Voltage hold on failure
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output

Order: Model HT1000AC-500mA-(options)

    TOP   

HT1000DC

HT1000DC imageOur HT1000DC is a DC only tester, with the ability to deliver up to 5mA to the EUT. Leakage current limits can be set with the rear panel knob from 0.25mA to 5mA. The tester stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. When testing stops due to a failure, the output voltage returns to zero and a buzzer sounds.

This tester allows the voltage to be set from the front panel, but does not offer a ground continuity check function, and does not have a NEMA 15-R receptacle on the front panel.

Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.

Output: 0-1000Vdc, set by front panel knob
Ripple: +/- 15%
Leakage Current Limit: .25mA-5mA set by rear panel knob
Dielectric Breakdown: Defeatable, by high frequency detection circuit
Test Time: Defeatable, 0-60 sec. by front panel knob
Ramp Time: Automatic, adjustable from 0-5 sec
Duty Cycle: 100%
Input Power: 120V , 1A

Option TM: TestMINDER automation software
Option RI: PLC Interface Board
Option VF: Voltage hold on failure
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output
240-220 or 240V operation (requires 3U enclosure)

Order: Model HT1000DC-(options)

    TOP   

HT1000DC-50mA

HT1000DC-50mA imageOur HT1000DC-50mA is a DC only tester, with the ability to deliver up to 50mA to the EUT. Leakage current limits can be set with the front panel knob from 2.5mA to 50mA. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to burn problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.

Regarding the ripple current in DC hipot testers, lower ripple requires larger filter capacitors, which store more power that is normally used to smooth the rectified waveform. In the case of a hipot tester, this stored power has the side effect of discharging into the EUT in the event of a failure. In order to keep the power that must be absorbed by the EUT within reasonable limits, we have struck a balance between lower ripple and excessive power. If your requirements dictate lower ripple, please let us know and we can quote accordingly. As a final note, we can build the tester to use 3 phase power to improve ripple and not increase the size of the filter capacitors.

Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.

Output: 0-1000Vdc, set by front panel knob
Ripple: +/- 15% (see text)
Leakage Current Limit: 2.5mA-50mA set by front panel knob
Dielectric Breakdown: Defeatable, by high frequency detection circuit
Test Time: Defeatable, 0-60 sec. by front panel knob
Ramp Time: Manual only
Duty Cycle: 100%
Input Power: 120V , 2A

Option TM: TestMINDER automation software
Option RI: PLC Interface Board
Option VF: Voltage hold on failure
Option XI: External interlock input
Option HVP: HV Probe
Option SV: Safe voltage output
240-220 or 240V operation (requires 3U enclosure)

Order: Model HT1000DC-50mA-(options)