In additon to our standard production line testers used to judge acceptability of products to product safety standards, Compliance West USA also offers hipot testers for special uses. This page details our offerings for 10kV-15kV hipot testers:
If you don't see exactly what you need, please contact us with your requirements.
HT10kVAC • HT10kVAC-25mA • HT10kVDC (15kVdc Tester) • HT10kac/dc (10kAC/15kDC Tester)
HT10kVDC-100mA (10kVac Tester) • HT10kac-500mA (10kVac Tester)HT10kVac
Our HT10kVac standard laboratory tester has AC output, for regular insulation work. Leakage current limits can be set with the rear panel knob from 0.5mA to 10mAac. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to examine problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.
Packaged in this enclosure. Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.
Option RI: PLC Interface Board
Option XI: External interlock input
Option SV: Safe voltage output
Option HAN: Carrying Handle
Option: 240 Vac input option (requires 3U enclosure)
HT10kVac-25mA
Our HT10kVac-25mA has AC output. Leakage current limits can be set with the front panel knob from 1mA to 25mA. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to burn problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.
Packaged in a 3U enclosure with voltage and current meters. Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.
Option RI: PLC Interface Board
Option VF: Voltage on hold failure
Option XI: External interlock input
Option SV: Safe voltage output
Option LC: Leakage current meter with hold on failure
240 - 240Vac input option (requires 3U enclosure)
Note: Due to the unique build and options packages, we cannot offer this tester as an on-line purchase.
HT10kVdc
Our HT10kVdc has DC output to 14kV. Leakage current limits can be set with the rear panel knob from 0.25mA to 5mA. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to burn problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.
Packaged in this enclosure with a voltage meter. Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.
Option RI: PLC Interface Board
Option XI: External interlock input
Option SV: Safe voltage output
Option HAN: Carrying Handle
HT10kVac/dc
Our HT10kVac/dc has AC and DC output. Leakage current limits can be set with the front panel knob from 0.5mA to 10mA ac and 0.25mA to 5mA dc. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to burn problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.
Packaged in a 3U enclosure with voltage and current meters. Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.
Option RI: PLC Interface Board
Option VF: Voltage on hold failure
Option XI: External interlock input
Option SV: Safe voltage output
240 - 240Vac input option (requires 3U enclosure)
HT10kVac-100mA
Our HT10kVac has AC output to 10kV with current capability to 100mA continuous duty. Leakage current limits can be set with the rear panel knob from 0.5mA to 100mA. Normal operation stops testing when a leakage current greater than the set amount is encountered. If this occurs, a buzzer sounds and the output voltage will return to zero.
Provided with a voltage and a current meter. Test leads are terminated in alligator clips and the provided calibration certificate is to the requirements of MIL-STD-45662-A, traceable to NIST. One year warranty on parts and labor. Weight 300 lbs approx.
Option RI: PLC Interface Board
Option XI: External interlock input
Option SV: Safe voltage output
Option TM: Computer Test Control
Option VF: Voltage Meter Hold on Failure
Option 240: 220 or 240V operation
Option ZOS: Requires the operator to reset the voltage knob to its minimum position before the TEST button can be pressed.
Option RF: Continuous Operation. Switch selects between timer and always on operation.
HT10kVac-500mA
Our HT10kVac-500mA has AC output with current capability to 500mA. Leakage current limits can be set with the front panel knob from 10mA to 500mA ac. Normal operation stops testing when a leakage current greater than the set amount is encountered. If this occurs, a buzzer sounds and the output voltage will return to zero.
Provided with a voltage and a current meter. Test leads are terminated in alligator clips and the provided calibration certificate is to the requirements of MIL-STD-45662-A, traceable to NIST. One year warranty on parts and labor. Weight 700 lbs approx. Enclosure is 24" wide by 22" deep by 29" tall.
See a video demonstrating an Arc Shutdown Test.
Option RI: PLC Interface Board
Option VF: Voltage on hold failure
Option XI: External interlock input
Option SV: Safe voltage output
Option TM: Computer Operation
Option ZOS: Requires the operator to reset the voltage knob to its minimum position before the TEST button can be pressed.
Option RF: Continuous Operation. Switch selects between timer and always on operation.
Option GC: Checks continuity from building safety ground to hipot frame. If this connection is broken, high voltage is disabled. Requires option XI. Banana jack on rear panel connects to building ground.
Option HVLR: Closes relay and lights LED when High Voltage is present.
Option UCT: Provides 20 turn pots to set under and overcurrent trip levels. Undercurrent trip allows tester to detect a broken lead or improper lead attachment.