Compliance West USA Hipot Testers Header

HT-3000: AC/DC output with ground continuity

HT-3000 Image

The HT-3000 AC/DC Hipot tester:0-2000Vac, to 20mA and 0-2800Vdc, to 5mA

  • The most user-friendly hipot/continuity tester on the market today, at an attractive price. Watch to see how easy it is to operate!
  • Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed.
  • Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel.
  • Simple test outcome judgement. Green lights mean pass - red lights mean fail. Failing tests sound a buzzer as well.
  • Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate included.
  • In-depth testing. Both Arc Dectection and Leakage Current circuits test the product for more accurate testing.
    RED lights and a buzzer leave no question if a failure has occurred.
  • Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™.
  • Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1.

The HT-3000 is a production line AC/DC Hipot Tester. This tester can test to UL, CSA and other safety agency production line requirements with either AC or DC voltage. In addition, it allows connection of a high voltage cable (supplied with the HT-3000) for special testing. See details on our Option HO page.

The HT-3000 can generate up to 2000Vac at 20mA or 2800Vdc at 5mA.
This tester performs the dielectric withstand and ground continuity production line tests required by UL and CSA.

For TUV, Nemko and other European agency production line testing, add the GF-30ac to conduct the additionally required High Current Ground Bonding Test. To conduct both tests with one setup, add the Test-Link.

High voltage and many other options are available as well. Our option list for the HT-3000 is below.

Provided with leads, manual and calibration certificate traceable to the NIST.
Compatible with our shift-by-shift function checker, the HTT-1.

Video: Using a Compliance West Hipot/Ground Continuity Tester

Video: Hipot Testing for Products without a Power Cord

Video: TestLink: Connection and Setup

    TOP

Use

This tester can test to UL, CSA and other safety agency production line requirements with either AC or DC voltage.

    TOP

Option J2 and J3: Jumpers for testing products without plugs
Option TL: TEST-LINK™ upgrade
Option HAN: Carrying Handle
Option TM: TestMINDER automation software
Option 240: 220/240V only operation.
Option AR: Auto Reset on Pass
Option RI: PLC Interface Board
Option LC: Leakage Current Display
Option LI: Line Current Measurement
Option LR: Line Resistance Measurement
Option AH: High Voltage Output (2500Vac, 20mA)
Option LLC: Low Current Trip Point (10uA min)
Option HVP: HV Probe
Option HTT-1: HTT-1 Hipot and Ground Continuity Function Checker

    TOP
AC output to 2000 Volts. DC output to 2800 Volts. Delivers up to 5mA and 10mA AC. Provided with arc detection circuit to properly detect Hipot failures.
Meets requirements for UL/CSA/IEC/CE production line testing. Logic controlled, One-Button testing. LED's indicate test progress. Upon failure buzzer sounds and test is terminated.
Output voltage, leakage current limit, voltage ramp time, and test duration are adjustable from the rear panel.
Ground continuity is defeatable for testing two wire products.
NEMA 5-15R receptacle provided on front panel for high voltage output makes for easy testing of finished products.
Automatic voltage ramp-down circuit eliminates residual voltage.
Operation instructions on rear panel.
Performs to safety Agency requirements for product line testing.
Calibration resistor mounted on rear panel for easy calibration.
All test leads included.
30 day trial- 1 year warranty