• Hipot Tester, 0-14KVdc @ 5mA
  • Product Views

Hipot Tester, 0-14KVdc @ 5mA

  • $3,660.00

HT-10KVPdc Hipot Tester, 0-14kVdc @ 5mA. Ships complete with cables, manual, and Calibration Certificate. Made in the USA. Calibration and Repair services available. Not sure - contact us!

Available Options

Reviews (0)

Write a Review

Note: HTML is not translated!
    Bad           Good


  • HT10000P AC: AC output to 10000 Volts. Delivers 1 through 8 milliamps. Custom outputs to 25 mA.
  • HT10000P DC: DC output to 14000 Volts. Delivers 1 through 5 milliamps.
  • Logic Controlled, One-button testing. LED indicators. Buzzer upon failure, test terminates. Test termination defeatable by switch on rear panel. Provided with arc detection circuit to properly detect hipot failures.
  • Rear panel adjustments; leakage limit, ramp time, test time and voltage.
  • Ergonomic design for safety and ease of use.
  • High voltage output jack.
  • Automatic voltage ramp-down circuit eliminates residual voltage.
  • Designed for product development and laboratory use.
  • High efficiency design, low power consumption.
  • All test leads included.
  • Calibrated to NIST standards.
  • 1 year warranty
  • HTT-1 and HTT-1RHipot and Ground Continuity Function Checker Compatible


Voltage Test TypeDC
Voltage Range0-14000 VDC
Current Range4 mA
Input Voltage Requirements108-132 V, 50 /60 Hz, 2A max
Fuse Requirements120 VAC
Arc DetectSeparate high Frequency circuit
Leakage DetectSeparate Low frequency circuit
Ground ContinuityN/A
Ground Continuity CurrentN/A
Test Time Range1 - 60 seconds
Ramp time Range1 - 5 Seconds
Voltage Meter Accuracy± 2 %
Current Meter Accuracy±0.1 mA
Resistance measure RangeN/A
Resistance auto offset RangeN/A
Resistance Measure AccuracyN/A
HV shutdown by Ground FailN/A
Duty cycle100%
Discharge Time (Resistive Load)
Transformer Output< 500 VAC
Pass/Fail Repeatability± 3 %
Output connectorHigh Voltage Jack
Display4 digits LED display
Test indicatorLed indicators
Failure IndicatorLed indicators and buzzer
PLC InterfaceNo
Voltage Hold on failureAvailable
Top Mounted handleNo
Test DefeatRamp Time, Test Time and Breakdown Fail
Autoreset on PassOptional
Operation Temperature15 - 40 °C
Relative Humidity Range0 - 90 % Non-condensing
Dimensions10" wide x 5" high x 12" deep
Weight17.5 Lb
CalibrationOne year calibration Certificate
Test CordsReturn lead, High Voltage Test Lead, Power cord
HTS/Schedule B9030.39.0100
What is in the boxReturn lead, High Voltage Test Lead, Power cord


Contact Us

Corporate Sales Office (USA)

Compliance West USA
650 Gateway Center Way Suite D
San Diego, CA 92102 USA

US Representatives

Product Update Bulletin

Newest Product: HT-3500S RF, "ruggedized" hipot tester

The HT-3500S RF tester is specifically designed for the challenges common to operating in the field. Along with heavy duty internal brackets and a sturdy, shock-absorbing case, this unit includes adjustable voltage output, voltage ramp, test time, leakage current and ground continuity limit settings - all controlled from an easy-to-access front panel. Call for pricing.

Read More

Available: 16A option for CDT-240

Perform one of the most difficult tests required with both speed and accuracy. The CDT-240 now offers a 16A option along with designed presets to implement the plug discharge test as described in IEC 61010, 60065 and 60335.

Read More

MegaPulse Defib 5P reaches EOL - Replaced by D5-PF

Compliance West USA is announcing the EOL (End-of-LIfe) of our MegaPulse Defib 5P series effective 07/14/2015. This unit has been replaced by our MegaPulse D5-PF advanced tester. Compliance West will continue to support, repair and calibrate the Defib 5P throughout the terms of any existing warranty agreements or up until the product's End-of-Support date. Please contact us with any questions.

Read More