Compliance West USA feels there is no need to spend more than necessary to obtain results required for approvals. Our MegaPulse Capacitor line is a case in point. Many times, manufacturers need to pretest or witness test only a small number of separate capacitor Surge testing requirements, but find that to do so they need to purchase a large base station/plug in solution. For these companies, a more cost-effective solution may be to purchase a MegaPulse or two. In many cases, the cost of an entire MegaPulse is less than the cost of the plug-in for other solutions. The MegaPulses are used with a general purpose oscilloscope for waveform capture and evaluation.
The MEGAPULSE Capacitor Series is designed to test capacitors in accordance with IEC384-14, Annex A, Table XVI. Two testers are offered, one performing the tests in the Table, Lines 1-4, and the other performing the tests in Line 5-10. The suite of testers outputs the maximum voltage required for each Line of the Table.
For the lines in BLACK type: Capacitor Series A.
For the lines in RED type: Capacitor Series B.
| Table XVI Line # |
Ct | Rp | Rs | Cp | Maximum Voltage |
|---|---|---|---|---|---|
1 |
0.25 |
234 |
62 |
7800 |
8000
|
2 |
0.25 |
234 |
45 |
7800 |
8000 |
3 |
0.25 |
234 |
27 |
7800 |
8000 |
4 |
0.25 |
234 |
27 |
0 |
8000 |
5 |
20 |
3 |
25 |
3300 |
4000 |
6 |
20 |
3 |
13 |
3300 |
4000 |
7 |
20 |
3 |
9 |
3300 |
4000 |
8 |
20 |
3 |
7 |
3300 |
4000 |
9 |
20 |
3 |
5 |
3300 |
4000 |
10 |
20 |
3 |
3 |
3300 |
4000 |
Purchase of the MegaPulse Capacitor Series A and B testers will allow complete testing of Capacitors in accordance with the test schematic shown in Annex A. MegaPulse Capacitor Series A and B ship with cables, graphs of theoretical and actual waveforms, and a Calibration Certificate. One-year warranty. Options include computer control/reporting or relay outputs for PLC control. MegaPulse Capacitor Series A MegaPulse Capacitor Series B.
The MEGAPULSE Capacitor Series is designed to test capacitors in accordance with IEC384-14, Annex A, Table XVI.
TOP
Option TMM: TestMinder MegaPulse Computer Control with multiple pulse capability.
Option IER: IEC 65 Figure 7b Switch
Option RI: PLC Operation Interface Relays
Option BNCV: Voltage BNC (1000:1) on front panel
Option P6015: High accuracy Tektronix probe for proper waveform measurement
Option IFD: Insulation Fault Detection Circuit