HT - 2000P
HT - 3000P

Video: HT-5000P Testing Overview
Video: Setting Test Time and Leakage Current Limits with a HT-5000P
Video: HT-5000P Setting and Using the Defeat Switches
| Voltage Test Type | AC/DC |
| Voltage Range | 0-5000 AC 0-6000 DC |
| Current Range | 1-10 mA AC 1-5 m A DC |
| Input Voltage Requirements | 117-127 V, 50 /60 Hz |
| Fuse Requirements | See Rear Panel for correct rating |
| Arc Detect | Separate high Frequency circuit |
| Leakage Detect | Separate Low frequency circuit |
| Test Time Range | 1 - 60 seconds |
| Ramp time Range | 1 - 5 Seconds |
| Voltage Meter Accuracy | ± 2 % |
| Duty cycle | 100% |
| Discharge Time (Resistive Load) | Factory Set 8 Sec max |
| Transformer Output | < 500 VAC |
| Pass/Fail Repeatability | ± 3 % |
| Output connector | High Voltage Jack |
| Display | 4 digits LED display |
| Test indicator | Led indicators |
| Failure Indicator | Led indicators and buzzer |
| Programable | No |
| PLC Interface | Optional |
| TestLink | No |
| Testminder | No |
| Voltage Hold on failure | Available |
| Top Mounted handle | Optional |
| Test Defeat |
-Ramp Time -Test Time -Breakdown Detect |
| Autoreset on Pass | Optional |
| Operation Temperature | 15 - 40 °C |
| Relative Humidity Range | 0 - 90 % Non-condensing |
| Dimensions | 10" wide x 5" high x 12" deep |
| Weight | 17.5 Lb |
| Calibration | One year calibration Certificate |
| Test Cords |
Return lead High Voltage Test Lead Power cord |
Option HAN: Carrying Handle
Option RI: PLC Interface Board