Compliance West USA Hipot Testers Header

HT-2800P: DC Output/Ground Continuity

HT-2800P

A DC hipot and ground continuity tester that's easy to use and priced right. All the features you need but none of the ones that you pay for but use only once.

The P suffix gets you precision leakage current and test time setup and viewing from the LCD meter. Adjustment is made with no HV output.

$1295 with a Calibration Certificate, manual and return lead. Always in stock. Ready to test out of the box.

Video: Using a Compliance West Hipot/Ground Continuity Tester
Video: Setting Test Time and Leakage Current Limits with a HT-2000P
Video: Hipot Testing for Products without a Power Cord
Video: TestLink: Connection and Setup

    TOP

HT-2800P DC Hipot/Ground Continuity Tester

Voltage Test Type DC
Voltage Range 0-2800
Current Range 1-5 mA
Input Voltage Requirements 117-127 V, 50 /60 Hz
Fuse Requirements 120 V, 1.5 A
Arc Detect Separate high Frequency  circuit 
Leakage Detect Separate Low frequency circuit 
Ground Continuity 3 ohm (Defeatable)
Test Time Range 1 - 60 seconds
Ramp time Range 1 - 5 Seconds
Voltage Meter Accuracy ± 5 %
Current Meter Accuracy N/A
Resistance measure Range N/A
Resistance auto offset Range N/A
Resistance Measure Accuracy N/A
HV shutdown by Ground Fail <  7 mS
Duty cycle 100%
Discharge Time < 1 Sec
Transformer Output < 500 VAC
Pass/Fail Repeatability ± 3 %
Output connector NEMA plug
Display 4 digits LED display
Test indicator Led indicators
Failure Indicator Led indicators and buzzer
Programable No
PLC Interface Optional
TestLink Optional
Testminder No
Voltage Hold on failure N/A
Top Mounted handle Optional
Test Defeat Ground Coninuity
Autoreset on Pass Optional
Operation Temperature 15 - 40 °C
Relative Humidity Range 0 - 90 % Non-condensing
Dimensions 9-1/4" wide x 4-3/4" high x 10" deep
Weight 14 Lbs
Calibration One year calibration Certificate
Test Cords

Return Lead, Power Cord

J2 and J3 Optional


    TOP

  • Adds high precision leakage current and duration settings to the user-friendly HT-2800 for better control of tests.
  • Allows no load setup of leakage current and test dwell times.
  • Once entered, leakage current and test dwell times can be referenced on the front panel display at any time.
  • Leakage currents can be set from 1-5mA in 0.1mA increments.
  • Dwell times can be set from 1-60 seconds in 1 second increments.
  • Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed.
  • Small and light. 9.25" wide x 4.25" high x 10" deep. 11 lbs. But rugged enough to test manufactured housing.
  • Ground continuity check is defeatable for testing two-wire products.
  • Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed!
  • J2 and J3 cords allow connection of pigtail power leads.
  • Simple test outcome judgement. Green lights mean pass - red lights mean fail. Failing tests sound a buzzer as well.
  • Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance.
  • Operation Instructions are printed on the rear panel for easy reference.
  • In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems.
    RED lights and a buzzer leave no question if a failure has occurred.
  • Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™.
  • Optional 120kohm calibration resistor can be mounted on the rear panel.
  • Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1.

    TOP

Ticket info - call 800-555-1212


RELATED PRODUCTS

What do customers ultimately buy after viewing this item?

HTT - 1

GF-30AC

TESTLINK™