Compliance West USA Hipot Testers Header

HT-10000: up to 10000 VAC or 14000 VDC

HT-10000 Image

  • HT10kVac: 10kVac, up to 10mA. $2395. Buy Now
  • HT10kVdc: 14kVdc, up to 5mA. $2495. Buy Now
  • HT10kVac/dc: 10kVac @ 10mA; 14kVdc@5mA. $3095. Buy Now
  • HT10kVa-25mA-I: 10kVac, up to 25 mA. Datasheet Contact factory for details and options.
  • HT10kVac-100mA: 10kVac, up to 100mA. Contact factory for details and options.
  • HT10kVac-500mA: 10kVac, up to 500mA. Contact factory for details and options.

Front panel voltage dial makes this unit easy to use.

Auto-ramp on low current models. Current limit and test time settings on front panel.

A variety of safety and convenience options are available.

Provided with leads, manual, and calibration certificate.

    TOP

Output:

  • HT-10kVac: to 10,000Volts ac. Leakage current 1 - 10mA AC.
  • HT-10kVdc: to 14,000Volts dc. Leakage current 1 - 5mA DC.
  • HT-10kvac/dc combines outputs and adds a current meter to the front panel. 3U enclosure.
  • Current capabilities of 25, 100 and 500mA available. Consult factory.

Pass/Fail Criteria:

  • Leakage Current: Adjustable via knob to any intermediate setting.
  • Arc Detection: Separate high frequency detection circuit for breakdown spike detection.

User Adjustments:

  • Test Time 1-60 sec., defeatable for operation while button is pressed.
  • Voltage Ramp Time .5-5 seconds, defeatable.
  • Leakage Fail Point: AC - 1 - 10mA DC - 1-5mA via knob.
  • Voltage Ramp Defeat applies voltage without ramp.
  • Timer Duration Defeat applies voltage only while TEST button is pressed.
  • Shutdown on Failure Defeat disables Arc Detection circuit.

Operation:

  • Voltage rampdown time: AC - .5 sec max; DC - 8 sec max.
  • Duty Cycle: 100%
  • Meter accuracy: ±3% 500-10kV

Physical:

  • HT10kac and HT10kdc: Weight 20 lbs. ac/dc: Weight 30 lbs.
  • HT10kac and HT10kdc: Dims 11.25Wx4.25Hx12D ac/dc 17Wx3UHx17D
  • Input power requirements: 114-127VAC.

    TOP

Option RI: Relay Isolated Remote Control.
Option SV: Safe Voltage Relay Option
Option XI: External Interlock
Option HAN: Handle for portability (Not on ac/dc model)
Option RF: Continuous Operation
Option LLC: High Accuracy Low Current Measurement (Not on ac/dc model)
Option VF: Voltage Hold on Failure (ac/dc model only)
Option 240: 220/230/240Volt mains (ac/dc model only)

    TOP

HT10000 AC: AC output to 10000 Volts. Delivers 1 through 10 milliamps. Custom outputs to 25 mA.
HT10000 DC: DC output to 14000 Volts. Delivers 1 through 5 milliamps.
Logic Controlled, One-button testing. LED indicators. Buzzer upon failure, test terminates. Test termination defeatable by switch on rear panel. Provided with arc detection circuit to properly detect hipot failures.
Rear panel adjustments; leakage limit, ramp time, test time and voltage.
Ergonomic design for safety and ease of use.
High voltage output jack.
Automatic voltage ramp-down circuit eliminates residual voltage.
Designed for product development and laboratory use.
High efficiency design, low power consumption.
Calibration resistor mounted on rear panel for easy calibration.
All test leads included.
Calibrated to NIST standards.
1 year warranty
HTT-1 Hipot and Ground Continuity Function Checker Compatible

    TOP

Ticket info - call 800-555-1212