The surge test described in this Table is conducted at 6000v maximum. Lower voltage testing may be done per Note 4.
GR-1089, Issue 1 and 2, Table 4-6, and Issue 3, Table 4-10:
MegaPulse 1.2x50/8x20-6-1 - Peak output voltage is adjustable up to 6000 volts minimum, peak short circuit current is 3000A minimum. A switch is provided for reversal of output polarity. Optional divider network available for oscilloscope connection.
Waveform generated is 1.2x50/8x20, VP= 6000V. To perform the Test, the front panel voltage meter is set to 6000V, or other value specified in Note 4.
Enclosure is 19 x 3U, rack mountable (3U enclosure)
Outputs are isolated.
MegaPulse 2x10s-5
Same as above, except 7000V output.
Option RI: PLC Interface Relay Board.
Option BNCV: 1000:1 Voltage BNC output
Option P6015: High accuracy Tektronix probe for proper waveform measurement