The surge test described in this Table is conducted at 2000v maximum. Lower voltage testing may be done per Note 4.
If testing to GR-1089 Issue 1 and 2, Table 4-6, and Issue 3, Table 4-10 is also to be done, specify the MegaPulse 1.2x50/8X20-6-1, as both tests can be conducted with one tester.
GR-1089, Issue 1 and 2, Table 4-5, and Issue 3, Table 4-9:
MegaPulse 1.2x50/8x20-2.5 - Peak output voltage is adjustable up to 2500 volts minimum, peak short circuit current is 1000A minimum. A switch is provided for reversal of output polarity. Optional divider network available for oscilloscope connection.
Waveform generated is 1.2x50/8x20, VP= 2500V. To perform the Test, the front panel voltage meter is set to 2000V, or other value specified in Note 4.
Enclosure is 19 x 3U, rack mountable (3U enclosure)
Outputs are isolated.
MegaPulse 1.2x50/8x20-2.5
Option RI: PLC Interface Relay Board.
Option BNCV: 1000:1 Voltage BNC output
Option P6015: High accuracy Tektronix probe for proper waveform measurement